GUIDE TO DOMESTIC BATHROOM LIGHTING REGULATIONS
PLEASE NOTE: THIS IS A GUIDE TO DOMESTIC SITUATIONS.
FOR NON-DOMESTIC SITUATIONS OR IF YOU ARE IN DOUBT,
WE RECOMMEND THAT YOU CONSULT A QUALIFIED ELECTRICIAN.
(IEE WIRING REGULATIONS 16th EDITION (Amd. 3) EFFECTIVE 1.1.2002).

ZONE KEY.
0 ALL LIGHT FITTINGS IN ZONE 0 MUST BE WATERTIGHT AND BE 12 VOLTS OR LESS. (IP67 OR IPX7).
1 ALL LIGHT FITTINGS IN ZONE 1 MUST BE SPLASH PROOF (IP44 OR IPX4).
PLEASE NOTE: MAINS VOLTAGE FITTINGS IN THIS ZONE MUST BE WIRED ON A SEPARATE CIRCUIT & PROTECTED BY A 30mA RESIDUAL CURRENT DEVICE (RCD).
2 ALL LIGHT FITTINGS IN ZONE 2 MUST BE SPLASHPROOF (IP44 OR IPX4).
3 ALL LIGHT FITTINGS IN ZONE 3 HAVE NO SPECIAL REQUIREMENTS.

Click Here for a more detailed and technical page on Bathroom Zones - 29Kb Pdf