                | One 12v battery as back 
                  up | The Mag8 only needs 1 x 12v 
                  battery as back up supply. The Mag4 has a built in transformer 
                  which converts 12v from the battery to 24v. |   
                | Unlimited number of call-points | Unlimited number of call-points 
                  can be connected to each zone on the Mag8. |   
                | 30 fire detectors per zone | Up to 30 fire detectors can 
                  be connected to each zone on a Mag8. Therefore the Mag8 is able 
                  to power a maximum of 60 detectors. |   
                | Individual zone fault identification | If there is a fault on a zone 
                  the panel is able to indicate which zone has a problem via lighting 
                  up the fault LED alongside the zone. This is situated on the 
                  front LED display board. |   
                | Sounder circuit fault identification | If there is a fault on a sounder 
                  circuit the panel is able to indicate which sounder circuit 
                  has a problem via lighting up the fault LED alongside the sounder 
                  circuit. This is situated on the front LED display board. |   
                | Fault identification | To help the end user or installer 
                  to determine the cause of the fault there are fault indication 
                  LED's located on the front LED display board. These LED's are 
                  marked as low battery, battery loss, no AC, earth, processor, 
                  zone power etc. |   
                | Individual zone isolate | The Mag8 can be programmed so 
                  that individual zones can be isolated (disabled) which allows 
                  an engineer/installer carry out maintenance work without the 
                  worry that the panel will go into fault condition. |   
                | One man test facility | The one man test facility enables 
                  an engineer/installer to test all detection devices connected 
                  to a zone one by one. The panel indicates its status via a series 
                  of bleeps plus the sounders come on for one second to confirm 
                  activation. |   
                | Class change facility | The class change facility is 
                  an input, which can be used to activate the sounders/bells connected 
                  to the panel via an external device. Class change facility would 
                  be used in places such as schools. |   
                | Repeater panel | The Mag8 has a facility which allows you to connect a repeater 
                    panel to the system so that it is possible to monitor the 
                    fire alarm system from a different part of the premises. |   
                | Fire relay | Device(s) which need to be activated 
                  when the panel is in fire condition can be connected to the 
                  fire relay i.e. magnetic door holders. |   
                | Fault relay | Device(s) which need to be activated 
                  when the panel is in fault condition can be connected to the 
                  fault relay i.e. fault indication light etc. |   
                | Plug in terminal 
                  blocks | For ease of installation 
                  the connection terminal blocks can be removed and placed back 
                  on the PCB as desired. |  
 
               
                
                
                | Max number of zones: | 8 8 (with zone expander card) |   
                | Main power supply: | 230V AC +- 10% |   
                | Standby power supply: | 2 x 12V (12V) Sealed lead acid batteries |   
                | Max current available: | 2 amps |   
                | Current consumption - mains failure: | 85mA |   
                | Sounder circuit 1: | 24V / 0.5A - 0.5A fuse |   
                | Sounder circuit 2: | 24V / 0.5A - 0.5A fuse |   
                | Auxiliary output:: | 24V DC - 0.5A fuse |   
                | Cabling: | Maximum 2.5mm diameter |   
                | Dimensions: 
 
 | 350(w) x 370(h) x 100(d) mm |   
                | Working temperature: | 0 to 40ºC |   
                | Storage temperature: | -20 to 60ºC |   
                | Humidity: |  0 to 95% |   
                | 
                      TECHNICAL HELPLINE: 0121 786 1881 |      |