Manufacturer
CentaurPlus C11 or C17
425 Coronet or
ChannelPlus H11/H17
Model
E
N
L
1
2
3
4
-
E
N
L
1,2,3
4
5
6
ACL-Drayton
-
-
-
-
-
-
-
-
-
-
-
-
-
LP111
-
N
L
4
1
2
3
-
-
N
L
4
3
1
2
LP711
-
N
L
4
1
2
3
-
-
N
L
4
3
1
2
LS111
-
N
L
4
1
2
3
-
-
N
L
4
3
1
2
LS711
-
N
L
4
1
2
3
-
-
N
L
4
3
1
2
Switchmaster 300
-
N,2
L
-
4
-
1
-
-
N,2
L
-
1
4
-
Switchmaster 980
-
N
L
-
4
-
1
-
-
N
L
-
1
4
-
TC
-
2
1
-
-
-
7
-
-
2
1
-
7
-
-
Tempus 1
-
N
L
4
1
3
2
-
-
N
L
4
2
1
3
Tempus 2
-
N
L
4
1
3
2
-
-
N
L
4
2
1
3
Danfoss Randall                        
103
4
5
6
2
3
-
1
-
4
5
6
2
1
3
-
103E
4
5
6
2
3
-
1
-
4
5
6
2
1
3
-
103E5
4
5
6
2
3
-
1
-
4
5
6
2
1
3
-
103E7
4
5
6
2
3
-
1
-
4
5
6
2
1
3
-
911
E
N
L
2
5
4
6
-
E
N
L
2
6
5
4
917
E
N
L
2
5
4
6
-
E
N
L
2
6
5
4
971
E
N
L
2
5
4
6
-
E
N
L
2
6
5
4
TS15
-
N
L
5,6
1
2
4
-
-
N
L
5,6
4
1
2
TS75
-
N
L
5,6
1
2
4
-
-
N
L
5,6
4
1
2
Honeywell                              
ST6100A
-
N
L
3
1
2
4
-
-
N
L
3
4
1
2
ST6100C
-
N
L
3
1
2
4
-
-
N
L
3
4
1
2
ST7000B
-
N
L
-
-
2
3
-
-
N
L
-
3
-
2
Horstmann                              
423 Emerald
E
N
L
5,6
3
-
4
-
E
N
L
5,6
4
3
-
423 Pearl Auto
E
N
L
5,6
3
-
4
-
E
N
L
5,6
4
3
-
424 Emerald
E
N
L/1
5
3
-
4
-
E
N
L/1
5
4
3
-
424 Pearl Auto
E
N
L/1
5
3
-
4
-
E
N
L/1
5
4
3
-
Centaur SC1
E
N
L
4
1
2
3
-
E
N
L
4
3
1
2
Centaur SC7
E
N
L
4
1
2
3
-
E
N
L
4
3
1
2
Pegler Sunvic                        
SP20
E
N
L
S
3
4
5
-
E
N
L
S
5
3
4
SP35
E
N
L
S
3
4
5
-
E
N
L
S
5
3
4
Potterton                              
EP4000
E
N
L
A,B,C,D
5
2
4
-
E
N
L
A,B,C,D
4
5
2
EP4001
E
N
L
A,B,C,D
5
2
4
-
E
N
L
A,B,C,D
4
5
2
EP4002
E
N
L
A,B,C,D
5
2
4
-
E
N
L
A,B,C,D
4
5
2
EP5002
E
N
L
A,B,C,D
5
2
4
-
E
N
L
A,B,C,D
4
5
2
Sangamo                              
409 form 8
-
N,3
L,5
1
6
-
2
-
-
N,3
L,5
1
2
6
-
410 form 8
E
4,5
3
6,7,8
2
-
1
-
E
4,5
3
6,7,8
1
2
-
M6
E
4
6
-
3
2
1
-
E
4
6
-
1
3
2
Smiths Industries                        
Centroller 30
E
1
2
-
-
3,6
4,5
-
E
1
2
-
4,5
-
3,6
Centroller 40
E
1
2
-
-
3,6
4,5
-
E
1
2
-
4,5
-
3,6
Centroller 50
E
2
1,5
-
-
-
4
-
E
2
1,5
-
4
-
-
Centroller Mk1
-
N
L
-
3
-
2
-
-
N
L
-
2
3
-
Centroller Mk2
-
N
L
-
3
-
2
-
-
N
L
-
2
3
-
Towerchron                          
DT71
-
N
L
-
3
2
4
-
-
N
L
-
4
3
2
QE1
-
N
L
1
3
2
4
-
-
N
L
1
4
3
2
T2001
-
N
L
-
-
-
7
-
-
N
L
-
7
-
-
T2001Q
-
N
L
-
-
-
7
-
-
N
L
-
7
-
-
Venner                              
Venner T10
E
N
L
-
2
1
3
-
E
N
L
-
3
2
1
Venotime
E
N
L
2
-
1
3
-
E
N
L
2
3
-
1

 

NOTE: Programmers The CentaurPlus, ChannelPlus and 425 Series models detailed
within the Programmer table do not have any SPARE or LINKING terminals. If spare
terminals have been used on the programmer being replaced then any connected
wires should be removed and re-connected into a separate piece of terminal block.

Timeswitches Terminal 1 on the CentaurPlus and Terminals 1,2 & 3 on the ChannelPlus
and 425 Coronet models detailed within the Timeswitch table are SPARE or LINKING
terminals. In the event that the number of spare terminals used on the timeswitch
being replaced exceeds those detailed above then any connected wires should be
removed and re-connected into a separate piece of terminal block.
Wires from different spare terminals should not be joined together.