WBS and BEAB approved.
Manufactured in the UK in a BS EN ISO 9002 registered factory.

7 and 10 litre.

Outer Casing:
White moulded thermoplastic.

1.0kW, 3.0kW @ 240V.
0.9kW, 2.8kW @ 230V.

Safety Features:
Dry-start cut-out.
Frost protection thermostat setting.
Thermostat setting lockable at 40C for hand washing.

Thermal Insulation:
Flame-retardant expanded polystyrene.

Thermostat Spec:
Capillary type, externally adjustable from 5°C to 90°C.

Water Container:
Polypropylene, tested to 0.5 bar (7psi).


Installation Details

Only Vented taps must be used with Streamline heaters.

Cable entry at rear or base of unit. Must be permanently connected to the electrical supply through a double-pole linked isolating switch with a minimum rating of 13A (3kW model) or 5A (1kW model).

Bracket, screws and plugs supplied for wall mounting. For undersink use the basic unit is inverted after the heating element has been rotated.

All installations should be fitted with a service valve to facilitate maintenance.
Minimum inlet pressure should be 0.34 bar (5psi) at which maximum flow is 5 litres/min.
A flow restrictor (available as an accessory) should be fitted for inlet pressures above 0.69 bar (10psi) to limit flow to 7 litres/min.
Supply direct from rising main or cistern (minimum head 4m) using 15mm o.d. pipe. Cistern supply is not possible for all outlet types; consult Heatrae Sadia for further advice.